NRG Technical Specifications

Product
Part Number

NRG-5-1DB

NRG-5-2DB

Form Factor

Rack-mountable: 2 NRG units = 1U (horizontal)

Connectivity
Network Connector

1x RJ45 with status LED indicators

GPIO

GPIO output port to signal error condition

Network
Network Standard

10/100 Base-T Ethernet

IP Addressing

IPv4, DHCP (default) and static IP

Command and Control
  • Web-based user interface compatible with most web browsers (Google Chrome recommended)
  • Rest-based API for easy integration available in future release
Physical
Product Dimensions

Overall dimensions (LxWxH)
1 RU (19 x 11.45 x 1.75 inches)
(48.3cm x 29.1cm x 4.4cm)

Dimension of NRG unit on tray
8.5 x 9.6 x 1.7 inches

Unit Weight

Single unit: 6.17 lbs (2800 g)
With packaging: 9.47 lbs (4300 g)
Dual unit: 10.58 lbs (4800 g)
With packaging: 14.33 lbs (6500 g)

Additional Features

Maximum number of devices powered per NRG unit
Avio 2 Series = 4
Extio 3 Series = 4
Maevex 6100 Series = 4
Maevex 6020 = 4
Monarch EDGE Series = 4
Monarch HDX & LCS = 5
QuadHead2Go Series = 5
ConvertIP Series = 5

Power Inputs (per NRG unit)

Number of AC inputs
2

Input voltage
100-240V a.c.

Input frequency range
50-60 Hz

Input current
5A @ 115V a.c. or 2.5A @ 230V a.c.

Power Outputs (per NRG unit)

Number of DC outputs
5

Output connector type
DIN4 female connector

Output voltage
12V 

Max current per output
output 1: 3A
outputs 2-5: 5A

Hardware & Software
Hardware Included

NRG-5-1DB
Rack tray with one (1) pre-installed NRG RPSU
One 6 foot, double ended DIN4 cable
4 x M3 device mounting screws
4 x Tray mounting screws

NRG-5-2DB
Rack tray with two (2) pre-installed NRG RPSU
Two 6 foot, double ended DIN4 cables
4 x Tray mounting screws

Hardware Required (sold separately)

IEC 60320 C13 power cable - ships with every compatible Matrox device

Accessories (sold separately)

NRG-5-PM
Spare or replacement power module

CAB-DIN4-6FT-4
Kit of four (4) 6-foot cables with DIN4 locking connector to connect Matrox appliances to 12v RPSU outputs

Environmental
Operating Conditions

Operational Environments
Temperature: 0 to 50 C (-4 to 176 F)
Humidity: 20 to 80% (non-condensing)
Atmospheric pressure: 660hPa (3,000 meters / 9,842 feet) to 1013hPa (0 meters / 0 feet)

Operating Sound Level (.12 meter distance) 44.1 dB - 63.1 dB (suitable for server and machine room installations)
Storage Conditions

Non-Operational/Transportation
Temperature: -20 to 80 C (32 to 122 F)
Humidity: 10 to 90% (non-condensing)
Atmospheric Pressure: 192hPa (12,000 meters / 39,370 feet)

Power Consumption

300W max

General
EMC/EMI Compliance

Emissions
FCC part 15 class A, CISPR 32 (EN 55032) class A, ICES-003 class A

Harmonic current
IEC/EN 61000-3-2

Immunity
CISPR 35 (EN55035)

Safety approvals
CAN/CSA C22.2 No. 62368-1-14; UL 62368-1 (2014), IEC 62368-1 (Ed. 2.0)

Warranty

2 year warranty